Vortox on FacebookVortox on Twitter121 S. Indian Hill Blvd
Claremont, CA 91711

Vortox on Google+Vortox on Pintrest Tel:
909.621.3843
Fax: 909.624.7212

Vortox on Instragram Contact Us Online

DA Breather Caps Header
DA Breather Caps

Vortox Air Technology, Inc. Breather Caps are designed to be used in both negative and positive pressure atmospheres. In negative pressure, the initial media filters out contamination in the air stream that could potentially harm internal components. When used in a positive pressure application, oil and dirt are captured in the filter media contained within the internal reservoir. As air flow stops, the oil will flow back to its source from the reservoir. The outer media serves as a secondary filter prior to the air re-entering the atmosphere oil free.

Filter Media

Standard Filter Media is a non-toxic, washable cellular foam. Alternate media of either steel or stainless steel mesh is also available.

Service Instructions

Periodically inspect for accumulation of dirt. Remove Breather Cap, wash in common detergent and rinse. Allow media to dry, then reinstall Breather Cap.

 

All models available in Stainless Steel upon request.

All models available in Stainless Steel upon request.

Breather Caps – DA Series:Slip-On Tube

breather-caps_da-series-slip-on-tube_standard-measurements

Metric Measurements

breather-caps_da-series-slip-on-tube_metric-measurements

* Not available with condensing chamber.